SCSI configuration

Each SCSI port is configured separately. Displays
include a list of attached devices for each bus.
Configurable options are:
• Port

bus

speed

• Synchronous

transfer

• Wide

transfer

• Initiator

ID

• Bus reset on startup
• Bus

termination

• Maximum LUNs per SCSI target
• Attached devices listed by bus number
Click on the individual bus for information on each
SCSI device.
Reset each port by clicking on the

Reset button.

Fibre Channel configuration

Configurable options include:
• Hard address assignment
• Busy

return

status

• Data

rate

• Connection

mode

• Hard address value
The port and node names are displayed.

Storage management

A list of attached SCSI devices is displayed. Click on
the individual bus or port for detailed information on
each device.
You may also reset SCSI ports on this page.
The following options are configurable:
• Boot

scan

• Boot

Fibre

delay

• SpeedWrite default (refer to

Modify System

Values

on page 23).

• Virtual Drive Response

Time & date configuration

Configures the real-time clock or access remote time
server. Configurable options are:
• Enable/disable Simple Network Time Protocol
• Time

server

• Time

zone

• Manually set time
• Manually set date

Mapping

Refer to

Map Devices

on page 17.

Bridge management

Refer to

Modify System Values

on page 23.

Configurable options are:
• User

name

• Admin

password

• Read Only user name
• Minimum

operating

temperature

• Maximum

operating

temperature

• Operating

temperature

warning

You may determine which FibreBridge you are
accessing by clicking on

Enable in the Identify

Bridge line. The FibreBridge ready light blinks. To
stop the blinking, change the

Identify Bridge

parameter to

Disabled.

You may restore defaults to the FibreBridge by clicking
on the

Restore button in the Restore Defaults line,

then clicking on

Submit and going to the Restart

page and restarting the FibreBridge.

Firmware Update

Refer to

Update Firmware

on page 25.

Advanced CLI configuration

The Advanced page allows you to input any CLI
command available through the FibreBridge.
1

Type in the CLI command.

2

Click the

Submit button: this is equivalent to

typing in the CLI command into a TCP/IP or
serial port CLI session.
A text field beneath the box will list the most
recent commands issued to the FibreBridge
through this page.
If you enter an incorrect parameter, the CLI
help text displays showing the parameters
available.

3

If your entry was correct, type
saveconfiguration

4

Click the

Submit button. Your changes are

implemented.

Help

Gives help information about the command line
interface commands and troubleshooting tips via links
to pages with help text for each category of options
and one link to the Troubleshooting Tips and FAQs
page on the ATTO website,

www.attotech.com

.

Contact information for ATTO technical support is on
the right. Help is always available by pressing any
word shown in red on the screen.