ATTO Technology 2400C/R/D User Manual

Page 40

Advertising
background image

vii

ATTO Technology Inc. FibreBridge Installation and Operation Manual

DisplayEventLogFilter

Filters the display of data for specified subsystems and levels if

DisplayEventLog

is enabled. Valid event log subsystem

entries are platform-dependent. For set commands, the final
parameter indicates whether or not events from the specified
subsystem and level are displayed.

Default: all all all
set DisplayEventLogFilter [subsystem | all] [level | all] [all

| none]

get DisplayEventLogFilter [subsystem | all] [level | all]

DisplayTraceLog

Displays the most recent page of trace log entries. The optional
parameter n is the number of lines to be displayed as a single
page with no user interaction. After the command has executed,
use +, - or = to scroll through the log. Type quit and press
Enter to exit the command.

DisplayTraceLog <n>

DisplayTraceLogFilter

Filters the display of data for specific ports if

DisplayTraceLog

is enabled.

set DisplayTraceLogFilter [FC | SCSI | all] [fp | sb | all]

[none | chkcond | all]

get DisplayTraceLogFilter [FC | SCSI | all] [fp | sb | all]

DumpConfiguration

Displays the FibreBridge configuration.

DumpConfiguration

DumpEventLog

Dumps the entire contents of the event log to the ExpressNAV
Advanced page text box, RS-232 or Telnet session.

DumpEventLog

DumpTraceLog

Dumps the entire contents of the trace log to the ExpressNAV
Advanced page text box, RS-232 or Telnet session.

DumpTraceLog

EmailFromAddress

Configures the Email address that the FibreBridge uses to
communicate with the Email server. Full Email address is a fully
qualified Internet Email address, not more than 128 characters
long.

set EmailFromAddress [full email address]
get EmailFromAddress

EmailNotify

Regulates Email notification.

Default: disabled.
set EmailNotify [enabled | disabled]
get EmailNotify

EmailNotifyAddress

Configures notification addresses. Index is a number 1-5. Full
Email address
is a fully qualified Internet Email address, not
more than 128 characters long. Warning level can be All,
Warning
, Critical or None. None means no Emails are sent;
Critical means only critical severity events sends an Email;
Warning means only warnings and critical events send Email,
and All means all warnings and critical events warrant an
Email.

set EmailNotifyAddress [index] [full email address]

[warning level]

get EmailNotifyAddress <index | all>

EmailPassword

Configures the password used to authenticate the login to the
SMTP Email server. The password must not be more than 64
characters. A password is not required if the Email server does
not require authentication.

set EmailPassword
Requires a SaveConfiguration command

EmailServerAddress

Configures the address of the server the FibreBridge must
contact in order to send out Email notifications.

set EmailServerAddress [IP address]
Requires a SaveConfiguration command
get EmailServerAddress

EmailUsername

Configures the user name used to authenticate the login to the
SMTP Email server. The user name must not be more than 128
characters. A user name is not required if the Email server does
not require authentication.

set EmailUsername
Requires a SaveConfiguration command
get EmailUsername

EthernetSpeed

Sets/displays the current speed of the Ethernet connection.
Choices are 10, 100, and Auto.

Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration Restart command
get EthernetSpeed [mp1]
If auto enabled, returned value in parentheses indicates

current speed

Advertising