ATTO Technology 2400C/R/D User Manual

Page 27

Advertising
background image

22

Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format.

Subject: [The Type of Event that Occurred]

Message Body:
This is a status message from [FibreBridge name]. Identifying information as
well as the most recent entries from the event log appear below.

*************** Unit Information ***************
Serial Number : [Serial Number]
IP Addresses: [IP Address1]

[IP

Address2]

*************** Event Log Entries ****************

[Listing of the ten latest event log entries]

Exhibit 3.0-6 Events triggering an Email message, severity level and explanation

.

Event

Severity

Level

Explanation

Aborted Command

Warning

A SCSI command discovers a command has been aborted.

Device Down

Warning

A target device has failed or become offline.

Hardware Error

Critical

A SCSI command discovers an unrecoverable target device failure.

Medium Error

Warning

A command terminated with an error condition that may have been caused by a
flaw in the target device’s physical medium or its recorded data.

Temperature

Critical

Unit’s internal temperature has increased to or is above the maximum operating
temperature or decreased to at or below the minimum operating temperature.

Temperature

Warning

Unit’s internal temperature has increased to or is within the unit’s maximum
operating temperature less the unit’s temperature warning offset or decreased to
or is within the unit’s minimum operating temperature plus the unit’s temperature
warning offset.

Unit Power On

Info

The unit has been powered up.

Voltage

Critical

A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level

......

VDDA (3.30V)

.......

VDDB (2.50V)

......

VDDC (1.50V)

.....

VDDD(1.35V)

Low

........ .......

5%

....................

4%

.......................

5%

..................

4.5%

High

...............

8%

....................

5%

......................

5%

.................

5%

Voltage

Warning

A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level

......

VDDA (3.30V)

.......

VDDB (2.50V)

......

VDDC (1.50V)

.....

VDDD(1.35V)

Low

........ .......

3%

....................

3%

.......................

3%

..................

3%

High

...............

5%

...................

3.5%

....................

3%

.........., .....

3%

Advertising
This manual is related to the following products: