ATTO Technology Inc. FibreBridge Installation and Operation Manual

Email messages provide error notification

Email notification allows the FibreBridge to send an
Email message to you, a network administrator or
other users when certain events occur. Serious error
messages are sent immediately, while messages for
less serious errors are sent every 15 minutes.
You may send Emails to up to five Email addresses
and designate which conditions prompt each Email
notification.
When an event occurs that has been designated as
requiring Email notification, the FibreBridge sends the
message; it cannot respond to a rejection by a server
for an invalid address. Ensure all Email addresses
typed in are valid.
Each Email is time stamped when it leaves as part of
the SMTP header information as shown in Exhibit 3.0-
5.
1

If you are not already in the ExpressNAV
interface, type the IP address of your

FibreBridge in a standard browser as found in

Using ExpressNAV

on page 27, click

Enter

Here, type in your user name and password,
and click

OK.

2

On the left hand menu, click

Remote Mgt.

3

The

Remote Management page appears.

4

Click on the

enabled radio button next to the

Email Notification heading.

5

Type in the sender address (Emails show this
name in the

From field).

6

Type in the SMTP Server IP address.

7

Type in the user name and password of your
SMTP Email account if your server requires it

8

Type in up to five Email addresses.

9

Choose

All, Warning, or Critical for each

Email address.

10 When all information is typed in, click

Submit.

Temperature

Warning

Yes

Yes

Unit’s internal temperature has increased to at or
within the unit’s maximum operating temperature
less the unit’s temperature warning offset or
decreased to at or within the unit’s minimum
operating temperature plus the unit’s temperature
warning offset.

Unit Attention

Info

No

Yes

A SCSI command discovers a unit attention
condition has occurred.

Unit Power On

Info

Yes

Yes

The unit has been powered up.

Voltage

Info

Yes

Yes

A monitored voltage level has increased or
decreased to within standard operating ranges.

Voltage

Critical

Yes

Yes

A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
Level

...

VDDA

......

VDDB

..... .

VDDC

........

VDDD

.............

3.30V

.........

2.50V

........

1.50V

.........

1.35V

Low

.......

5%

..............

4%

............

5%

.........,..

4.5%

High

....

8%

............

5%

..... ....

5%

...........

5%

Voltage

Warning

Yes

Yes

A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
Level

...

VDDA

......

VDDB

..... .

VDDC

........

VDDD

.............

3.30V

.........

2.50V

........

1.50V

.........

1.35V

Low

.......

3%

..............

3%

..........

3%

.........,..

3%

High

.....

5%

..........

3.5%

... ......

3%

...........

3%

Event

Severity

Level

Extended

Traps disabled

Extended

Traps enabled

Explanation