Learn the countdown timer, Timer; learn – Watlow Series 935B User Manual

Page 30

Advertising
background image

30

Watlow Series 935B User’s Manual

Configuration Menu

[``In]

Input Type

[`C_F]

Celsius/Fahrenheit

[``rL]

Input Range Low

[``rH]

Input Range High

[`Ot1]

Output 1 Function

[`Ot2]

Output 2 Function

[`rts]

Remote Timer Start

[dISP]

Display Default

[ALtY]

Alarm Type

[AhYS]

Alarm Hysteresis

[tIM]

Timer Function

[Strt]

Start Timer

[`rdY]

Timer Ready Band

[``St]

Signal Time

Operations Menu

[`Aut]

Auto-tune

[tMr]

Countdown Timer

[IdLE]

Idle

Key Timer Information

• The timer requires Output 1 to work as either a heat or as a cool output.
• The 935B timer is a function of Output 2, a switched dc output.
• Hours: minutes (hh:mm) or minutes:seconds (mm:ss)

choices reside in Output 2

[`Ot2]

.

• Timer set-up occurs in two locations,

in the Configuration Menu and the Operations Menu.

,

starts the timer.

.

stops the timer.

[dISP]

choices set up the timer display (see p. 18).

• LED colon flashes when timer runs.

LED colon ON steadily when timer is not running.

Configuration Menu set-up includes: (see p. 18)
• Output 1

[`Ot1]

; heat

[hEAt]

or cool

[COOL]

• Output 2

[`Ot2]

; timing interval,

hours:minutes

[thM]

, or minutes:seconds

[tMS]

• Remote Timer Start

[`rts]

choices:

1. Manual start

[`off]

2. Remote Timer Start

[tmr]

3. Front Panel Lockout

[`fpl]

• Timer (Output 2) function

[tIM]

hours: minutes or minutes:seconds

(

[thm]

or

[tms]

) can perform one of four possible actions after timing:

1. Turn ON, also called, “delay ON”

[dLon]

2. Turn off, also called, “delay off”

[dLof]

3. Toggle ON, also called, “signal ON”

[sgon]

4. Toggle off, also called, “signal off”

[sgof]

• Start timer function

[Strt]

choices:

1. Immediate start

[IMd]

2. Start once inside a ready band

[`rdy]

3. Start once inside a ready band,

acknowledging

[rdya]

with a

ß

press

4. Start immediately on control power up

[PWr]

without waiting for

Ready Band temp. or

,

press.

• Ready band width

[`rdy]

above and below set point: degrees

• Signal time

[``St]

(if applicable) duration: seconds

Operations Menu set-up includes: (see p. 12)
• Countdown Time

[tMr]

:

hours:minutes or minutes:seconds

• Idle Set Point Type

[IdLE]

, two choices:

1. Track primary set point
2. Set an idle set point

The next page presents this information
in graphic format with additional detail.

30

15

45

0

Learn the Countdown Timer

Advertising