<8. Detailed Data Setting>

8-14

IM 11M12A01-04E

8.7.3 Setting Fuels

8.7.3.1

Input Parameters

The analyzer calculates the moisture content contained in exhaust gases. The following sets forth

the fuel parameters necessary for calculation and their entries. The moisture quantity may be

mathematically expressed by:

Moisture quantity =

=

=

=

where,

Ao : Theoretical amount of air per unit quantity of fuel, m

3

/kg (or m

3

/m

3

)

............ 2 in Table 8.16

G: Actual amount of exhaust gas (including water vapor) per unit quantity of fuel,

m

3

/kg (or m

3

/m

3

)

Gw : Water vapor contained in exhaust gas per unit quantity of fuel (by hydrogen

and moisture content in fuel), m

3

/kg (or m

3

/m

3

)

............ 1 in Table 8.16

Gw1: Water vapor contained in exhaust gas per unit quantity of fuel (moisture content

in air), m

3

/kg (or m

3

/m

3

)

Go: Theoretical amount of dry exhaust gas per unit quantity of fuel, m

3

/kg (or m

3

/m

3

)

m: Air ratio

X : Fuel coefficient determined depending on low calorific power of fuel, m

3

/kg (or m

3

/m

3

) ... 3 in Table 8.16

Z : Absolute humidity of the atmosphere, kg /kg ....... Figure 8.4

(water vapor caused by combustion and water vapor contained in the exhaust gas)

..

actual exhaust gas(including water vapor) per fuel

+ (water vapor contained in air for combustion)

x 100

Gw + (1.61 x Z x m x Ao)

Go + Gw + (m - 1) Ao + (1.61 x Z x m x Ao)

x 100

Gw + (1.61 x Z x m x Ao )

X + Ao x m

x 100

Gw + Gw

1

G

x 100

..... Equation 1

............ Equation 2

Fill in the boxes with fuel parameters in Equation 2 above to calculate the moisture content. Use Ao,

Gw and X shown in Table 8.16. If there are no appropriate fuel data in Table 8.16, use the following

equations for calculation.
Find the value of “Z” in Equations 1 and 2 using Japanese Standard JIS B 8222. If a precise

measurement is not required, obtain the value of “Z” using a graph for the absolute humidity indicated

by a dry and wet bulb hygrometer.