Figure 5: a poor choice of mounting locations – Boltek EFM-100 v.2 User Manual

Page 14

Advertising
background image

C H A P T E R 2 - I N S T A L L A T I O N

8

Mounting the field mill close to tall objects will result low readings as the tall object will

shield the field mill sensor.

- - - - - - - - - - - - - -

+ + + +
+ + + + + + + + + + +

Figure 5: A poor choice of mounting locations

Avoid mounting the field mill in a location where it will be shielded by buildings, tree, or

other tall objects. Mount your field mill with similar considerations given to an

anemometer.

Figure 6: An excellent choice of mounting locations