Nalog, Utput – Boltek EFM-100 v.2 User Manual

Page 16

Advertising
background image

C H A P T E R 2 - I N S T A L L A T I O N

10

Analog Output

Analog output is available on the EPM-1 Power Module. Output voltage is 1V per kV/m

differential, ranging from +20V corresponding to +20kV/m to -20V corresponding to

-20kV/m. Note that EPM-1 connections are directly connected to the field mill and a
lightning hazard exists at those connections.

LIGHTNING HAZARD

EPM-1 connections are not optically isolated from the roof mounted field

mill. Dangerous voltages may occur should lightning strike at or near the

field mill.

Figure 8: EPM-1 Voltmeter Connections – Differential (Preferred Connection)

If a differential connection is not possible a single-ended connection may be made.

Figure 9: EPM-1 Voltmeter Connections – Single Ended

Advertising