Figure 14: efm-100 field mill connections – Boltek EFM-100 v.2 User Manual

Page 19

Advertising
background image

C H A P T E R 2 - I N S T A L L A T I O N

13

Figure 14: EFM-100 Field Mill Connections

Power Connector

Connect the black cable from the field mill’s power connector to the EPM-1 Power
Module’s field mill power connector. The cable supplies 12VDC to the field mill and

carries the analog output signals back to the EPM-1. See the Lightning Hazard caution in

the EPM-1 Analog Output section of this manual.


Fiber Optic Connector

Connect the orange fiber optic cable from the field mill’s fiber optic connector to the

EFA-10’s fiber optic connector. The fiber optic cable carries electric field data from the

field mill to the EFA-10 and ultimately to your computer. See the detailed drawings of the
fiber optic connector and note the keyway and locking tabs on the connectors. Orient the

key and locking slots properly on the male connector before attempting to insert the male

connector into the female connector.


Ground Connector

Connect the connector end of the green ground wire to the field mill ground connector.

The other end of the green ground wire connects to the field mill mount’s ground

connection. When mounting the field mill it is important to properly ground the field mill
and the field mill mount. The field mill is grounded through the green ground wire. The

field mill mounting hardware (mast and/or tripod) needs to be grounded though suitable

sized copper ground wire to your building central ground point. See Grounding Detail

for more information.