C H A P T E R 3 – C O N F I G U R I N G T H E S O F T W A R E

23

Field Mill Selector

Select the field mill for which you would like to enable or disable Very High Field Alarm.

Setpoint

Very High Field Alarm Setpoint is the magnitude of electric field required to trigger a Very High

Field Alarm. For example, with a setpoint of 1 kV/m the alarm will activate if the field goes above 1
kV/m or below -1 kV/m.

Delay

The Very High Field Alarm Delay is the length of time the field magnitude must remain above the
setpoint before the alarm is activated. If the electric field magnitude drops below the setpoint before

the delay expires the delay timer will be reset. For example, with a delay of 30 seconds and setpoint

of 1 kV/m the electric field must remain above 1 kV/m or below -1 kV/m for 30 seconds before the

alarm activates.

Duration

Very High Field Alarm Duration is the length of time the Very High Field Alarm will remain active

once the field drops below the alarm setpoint.

WAV File Checkbox

Check the checkbox to enable the playing of WAV file sound when the Very High Field Alarm

activates. Clear the checkbox to disable the playing of the WAV sound.

WAV Filename

The WAV Filename is the file which will play out the computer speakers when the Very High Field

Alarm is activated.
Click on the Browse icon

to select the WAV file from a list.

Click on the Play icon

to listen to the selected WAV file

WAV Repeat Interval

Enter the number of seconds between repeats of the WAV sound.