Ptions, Ogging, Figure 23: efm options – data logging – Boltek EFM-100 v.2 User Manual

Page 33

Advertising
background image

C H A P T E R 3 – C O N F I G U R I N G T H E S O F T W A R E

27

EFM Options: Data Logging

Figure 23: EFM Options – Data Logging

Field Mill Selector
Select the field mill for which you would like to configure data logging.

Enable Data Logging Checkbox

Check the Enable Data Logging checkbox if you would like field mill data to be logged to the hard
drive for the field mill selected in the selection box above. Logged data is viewable using the

EFMView Electric Field Mill Data Viewer. Select File…Open… on the main menu to view the data

file. Logging data will consume approximately 1.3 megabytes of hard disk space per field mill per

day.
Data files have a filename consisting of the field mill name, the file date, and a efm suffix. For

example: “Shop Roof-03252004.efm”. Data files are comma delimited ASCII text files allowing the

files to be loaded into spreadsheets or other third party software.


High Resolution Checkbox

When the High Resolution box is checked, it will store the EFM-100 data 20 times per second.

Leaving it unchecked will store the data 2 times per second. Please note when this option is enabled,

it will also increase the file size.

Logfile Location
This is the directory where the data files are stored. Click on the Open icon

to browse for the

directory.