Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual

Page 128

Advertising
background image

112

Brocade Network Advisor SMI Agent Developer’s Guide

53-1003159-01

Alert indications

4

Core8

Change in operational status for port.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and
MessageID=Core8

AlertingManagedElement

COP of
Brocade_SwitchFCPort

AlertingElementFormat

COP

AlertType

Device Alert

OtherAlertType

Port Alert

AlertSubType

FC Port operational
status modified

PerceivedSeverity

5 (Major)

ProbableCause

123

SystemCreationClassName

Brocade_Switch

SystemName

Switch WWN

ProviderName

Brocade_AlertIndication
Provider

OwningEntity

SNIA

Message

<Device Unique
Identifier> status
changed to <Port
Status>

MessageArguments

SwitchFCPort WWN,
Switch

Core 10

User login failure
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and MessageID=Core
10
How to trigger: Telnet to the switch and
provide an incorrect password.
NOTE: BRCD2 is now replaced with

Core10. Core 10 indication is
supported only for FOS switches.
This indication is not delivered if
SNMP registration fails.
Core 10 indications are delivered
when trackChangeset and SNMP
forward options are enabled in
switch.

AlertingManagedElement

COP of Brocade_Switch

AlertingElementFormat

COP

AlertType

Security

OtherAlertType

N/A

AlertSubType

User Login Failure

PerceivedSeverity

3 (Warning)

ProbableCause

123

SystemCreationClassName

Brocade_Switch

SystemName

Switch WWN

ProviderName

Brocade_AlertIndication
Provider

OwningEntity

SNIA

Message

<Device Type> <Device
Unique Identifier> user
<User> had login failure

MessageArguments

Device Type = Switch;
Unique Identifier = WWN;
User = UserName

TABLE 14

Supported alert indications (Continued)

Message ID

Trigger

Property

Value

Advertising