background image

114

Brocade Network Advisor SMI Agent Developer’s Guide

53-1003159-01

Alert indications

4

BRDC6

SNMP traps turned on by Track Change
On was turned off.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=BROCADE and
MessageID=BRCD6
How to trigger: Use the trackchangesset
CLI command to turn off the SNMP traps.
NOTE: BRCD6 indication is supported

only for FOS switches and is not
delivered if SNMP registration is
failed.

AlertingManagedElement

COP of Brocade_Switch

AlertingElementFormat

COP

AlertType

Other

OtherAlertType

Switch Alert

AlertSubType

Track Change Off

PerceivedSeverity

2 (Informational)

ProbableCause

123

SystemCreationClassName

Brocade_Switch

SystemName

Switch WWN

ProviderName

Brocade_AlertIndication
Provider

OwningEntity

BROCADE

Message

Alert configuration for
login, logout, orconfig
updates was turned OFF
for Switch <WWN>

MessageArguments

WWN = string Switch
WWN

BRCD7

The element (port) identified by
AlertingManagedElement is up.
Query: SELECT * FROM
CIM_AlertIndication WHERE
OwningEntity=SNIA and
MessageID=BRCD7
How to trigger: Telnet to the switch and
run the CLI portenable portnumber to
enable a connected port, such as an
E_Port, F_Port, or L_Port.

AlertingManagedElement

COP of
Brocade_SwitchFCPort

AlertingElementFormat

COP

AlertType

Other

OtherAlertType

Port Alert

AlertSubType

Up

PerceivedSeverity

2 (Informational)

ProbableCause

123

SystemCreationClassName

Brocade_Switch

SystemName

Switch WWN

ProviderName

Brocade_AlertIndication
Provider

OwningEntity

BROCADE

Message

Port <PortWWN> of
Switch <SwitchWWN> is
up

MessageArguments

SwitchFCPort WWN
Switch WWN

TABLE 14

Supported alert indications (Continued)

Message ID

Trigger

Property

Value

Advertising