Brocade Network Advisor SMI Agent Developers Guide v12.3.0 User Manual

Page 99

Advertising
background image

Brocade Network Advisor SMI Agent Developer’s Guide

83

53-1003159-01

FC routing

3

Backbone-to-edge device sharing (no FCIP configured
in backbone)

Figure 40

shows the data model for backbone-to-edge device sharing. If only the backbone

fabric is being managed through Brocade Network Advisor, then only instances in the
BackBone fabric view are discovered. If only the edge fabric is being managed through
Brocade Network Advisor, refer to the

“Limitations”

section. If both the backbone and the edge

fabrics are being managed through Brocade Network Advisor, then all instances and
associations are discoverable.

In the case of backbone edge device sharing, there is only one front phantom domain and two
xlate phantom domain switches. On the Edge fabric side, there is one front domain and one
xlate domain switch instance created. On the BackBone fabric side, there is only an xlate
domain switch created and no front phantom domain. Because the xlate phantom domain
switch is always behind the front phantom domain switch, the backbone switch itself
represents the front phantom domain. In addition to the logical port instance on the front
phantom in the edge fabric, FOS creates another instance of the logical port on the backbone
logical switch. This is the logical port instance that is connected to another logical port
instance on the xlate phantom through a SANActiveConnection.

Advertising