- 44 -

Following is a brief description for each item and its specific operations:

„ Size (GB) – the total HDD storage in GB (Giga-Byte) for Alarm Record and Normal

Record respectively. This item is just for information. Please refer to

Section 6.6.1

for

more detailed information and setup of each individual HDD.


„ Auto Overwrite – automatic overwrite of the recorded video/audio from HDD#1 when

the Alarm/Normal Record disk drive capacity reaches the end of the last HDD. If Auto
Overwrite is disabled and the Alarm/Normal Record disk drive capacity reaches the end,
the system will not overwrite the recorded video/audio, and hence not record
Alarm/Normal video/audio, until the user presses the Alarm Reset button. Press
ENTER

to check/uncheck this item. The default setting is “ˇ” - checked.


„ HDD Full Action – actions when Alarm/Normal Record disk drive capacity reaches the

end of the last HDD. Press ENTER to check/uncheck this item. The default setting is
“ˇ” - checked.


„ Duration – response duration to define at most how long (in seconds) the Alarm Out

relay and the Buzzer will keep being triggered after the corresponding partition, Alarm
Record or Normal Record, is full. Press +/- buttons to adjust the value (3 seconds - 60
minutes, discrete, ‘-‘ for ‘Forever’).


„ Alarm Out – to define which Alarm Output will be triggered when the corresponding

partition, Alarm Record or Normal Record, is full. Press +/- buttons to select none (N/A)
or one of the Alarm Outputs (1-4).


„ Buzzer – to activate the internal Buzzer or not when the corresponding partition, Alarm

Record or Normal Record, is full. Press ENTER

to check/uncheck this item. The

default setting is “ˇ” - checked.


„ Log – to log to event logs or not. Press ENTER to check/uncheck this item. The

default setting is “ˇ” - checked.

„ E-mail – to send the event e-mail to remote station or not. The e-mail will be sent to the

predefined receivers when the event is triggered. Press ENTER to check/uncheck this
item. The default setting is “–” - unchecked.