Troubleshooting the viper pro system, Viper pro troubleshooting information, Chapter – Seed Hawk Raven 2011 User Manual

Page 199: General issues

Advertising
background image

CHAPTER

11

Manual No. 016-3001-003

189

Chapter 11

Troubleshooting the

Viper Pro System

This chapter contains information on troubleshooting the Viper Pro system. Please read through all sections in
this chapter before contacting technical support, as many common questions are answered here.

Viper Pro Troubleshooting Information

This section contains information about possible issues and solutions for the Viper Pro

system

.

General Issues

Issue

Possible Cause

Solution

Viper does not
power up.

• No power to unit

• Check for +12VDC on pin 16 of the Viper power cable.

• Blown fuse

• Check for continuity in 10 amp fuse in Viper power cable.

• Poor ground

• Make sure that pin 1 is connected to the battery ground.

CAN nodes not
detected.

• No power to CAN nodes

• Verify that there is 12 volt power and ground to the CAN node's

logic power

• Weak or dirty power to

the CAN nodes

• Verify that the 12 volt power to the CAN node is coming from the

switch relay that is connected to the battery

• Water in CAN nodes

• Do not direct any pressure or wash stream directly at the CAN

node(s) to prevent water and moisture from building up in the
nodes.

• Corrosion in CAN

connections

• Disconnect and clean the CAN connections.

• Broken cable to node

• Repair or replace cable.

• Low power voltage

• Verify at least +10VDC at node.

Touch screen does
not respond to touch

• Area touched does not

include a selectable
function

• Touch an area of the screen that contains a selectable function.

• System is busy

processing a previous
request

• Wait for system to finish processing previous requests.