Pin Designations and Voltage Readings

The following tables show the following pin designations and voltage readings.

Note:

In a non-CAN system if a +5 voltage reading is not present, disconnect the Speed Sensor cable. If
the voltage reading is restored, test the Speed Sensor cable as described in

Appendix G, Testing

the Speed Sensor Extension Cable.

Testing the Flow Meter Cable

1.

Press Product Control.

2.

Press the Data Box 2.

3.

Enter the number ‘1’ in the Meter Cal field and press OK.

4.

Press Tally Registers.

Pin Location

Designation

2 o'clock

Ground

10 o'clock

Power

6 o'clock

Signal

Pin Connections

Voltage

2 o'clock to 6 o'clock

+5 Volts

10 o'clock to 2 o'clock

+5 Volts