MS-2 & MS-4 Series Manual — P/N 51512:G2 10/18/2011

27

Installation of Optional Modules

Installation

The following steps must be followed when installing each of these modules:

1. Remove all power (AC and DC) from the FACP before installing the modules.
2. Cut jumper JP1 (for connectors J3 and J5) and/or JP2 (for connectors J4 and J6) on the main

circuit board to allow the control panel to supervise the placement of any installed option
module.

3. Install the two supplied metal standoffs in the locations indicated. These standoffs provide the

required earth ground protection.

4. Carefully plug the connectors on the option module into connectors J3 and J5 or J4 and J6 on

the FACP main circuit board, being careful not to bend any pins.

5. Secure the option module to the standoff on the main circuit board with the supplied screws.
6. When the installation has been completed, connect the wiring to the modules as indicated in

the following sections.

7. Test system for proper operation.

4XTMF Transmitter Module Installation

The 4XTMF provides a supervised output for a local energy municipal box transmitter in addition
to alarm and trouble reverse polarity. A jumper option allows the reverse polarity circuit to open
with a system trouble condition if no alarm condition exists. A disable switch allows disabling of
the transmitter output during testing to prevent accidental calling of the monitoring service.

Local Energy Municipal Box Service (NFPA 72 Auxiliary Fire Alarm Systems):

Supervisory Current: 5.0 mA
Trip Current: 350 mA (subtracted from notification appliance power)
Coil Voltage: 3.65 VDC

ON

1

2

3

4

5

6

7
8

ON

1

2

3

4

5

6

7
8

ON

1

2

3

4

5

6

7
8

SUPERVISORY

SUPERVISORY

SUPERVISORY

SUPERVISORY

TROUBLE

TROUBLE

TROUBLE

TROUBLE

MAINTENANCE

MAINTENANCE

MAINTENANCE

MAINTENANCE

FIRE ALARM

FIRE ALARM

AC

POWER

NAC

DISABLE

NAC

FAULT

SYSTEM

TROUBLE

POWER

TROUBLE

WALK

TEST

ALARM

SILENCE

ZONE

DISABLE

FIRE ALARM

FIRE ALARM

RESET

WALK

TEST

ALARM

SILENCE

ACK

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE

ENABLE/DISABLE

3

4

2

1

TB
1

TB
2

TB
3

TB5

TB
6

TB7

J1

B+ B- B+ B-
NAC 1 NAC 2

+ - + -

Nonreset Reset

B+ B- B+ B-
ZONE 1 ZONE 2

B+ B- B+ B-
ZONE 3 ZONE 4

C TRBL NORM
TROUBLE

C NC NO

ALARM

SUPV

C NC NO

J3

J5

J4

J8

J7

J9

TB8

J6

JP1

JP3

SW1

BATTERY

HOT NEUT EARTH

TR
A

N

SF
O

R

M

E

R

1

TRA

N

SF
ORM

E

R 2

SW2 SW3

JP2

EARTH BATT CHG

CLASS A

CONVERTER

Figure 2.12 4X Option Module Connection to MS-4

J3

J5

J4

J6

JP1 Jumper
Cut to install
module on J3 & J5

JP2 Jumper
Cut to install module on J4 & J6

Standoffs

(when using

J3 & J5

ms4bord2.wmf

Standoffs

(when using

J4 & J6