<ESC>k<n>

select font type LQ

<n> =

0

Roman

1

Sans Serif

2

Courier

3

Prestige

4

Script

5

OCR-B

6

OCR-A

<ESC>K<n1><n2>

graphics 60 dpi

Formula:

n = length of graphics data
<n2> = INT (n/256)
<n1> = n MOD 256

<ESC>l<n>

set left margin

narrow printer

wide printer

<n> =

1 - 80

1 - 136 (10 cpi)

1 - 96

1 - 163 (12 cpi)

1 - 120

1 - 204 (15 cpi)

1 - 136

1 - 232 (17.1 cpi)

1 - 160

1 - 272 (20 cpi)

<ESC>L<n1><n2>

graphics 120 dpi

Formula:

n = length of graphics data

<n2> = INT (n/256)
<n1> = n MOD 256

<ESC>M

set character density to 12 cpi (Elite)

*

*

*

*

*

<ESC>n

locking shift 2 (LS2)

<ESC>N<n>

set space before perforation (perforation skip)

<n> = 1 - 127

*

*

*

*

*

<ESC>o

locking shift 3 (LS3)

<ESC>O

reset perforation skip

<ESC>p<1>

proportional spacing ON

<ESC>p<0>

proportional spacing OFF

<ESC>p1

proportional spacing ON

<ESC>p0

proportional spacing OFF

<ESC>P

set character density to 10 cpi (Pica)

<ESC>P<1>

proportional spacing ON

<ESC>P<0>

proportional spacing OFF

<ESC>q<n>

select character representation

IBM

IBM

Epson

Epson

IBM-

MTPL

Propr.

Propr.

FX850

LQ850+

AGM

Code

Function

XL

XL24

FX1050

LQ1050+

List of available control codes