Protocol description

Data flow control XON/XOFF

The printer signals an XON (DC1 ASCII 11 hex., 17 dec.) via the TxD line
when it is ready to receive data.

XOFF (DC3 ASCII, 13 hex., 19 dec.) is transmitted via the TxD line by the
printer when

– the printer is set Offline,
– there is a paper end,
– a hardware error occurs,
– the data buffer is full.

Make sure that on the computer side a program is installed which supports
XON/XOFF control!

Data flow control Robust XON/XOFF See also section XON/XOFF. With Robust XON/XOFF the condition of the

printer (XON or XOFF) is transmitted by the TxD line.

Enquire printer status ENQ/STX

With the code ENQ (ENQ ASCII, 5 hex., 5 dec.) the programmer can requ-
est the printer status. Upon this request the printer sends a status byte
which can be evaluated by the programmer

.

Status byte:

Bit 0

1

= BUSY

Bit 1

1

= Offline

Bit 2

0

= Paper End

Bit 3

1

= always 1

Bit 4

1

= Cover open

Bit 5

1

= Buffer Overflow

Bit 6

1

= Paritys or Frame Error

Bit 7

0

= always 0

With the STX code (STX ASCII, 2 hex., 2 dec.) the resulting possible
printer error message (parity error, buffer overflow) is cleared.

Serial interface RS232C/V.24

B - 6