Orion fixed network and migratable endpoints – Badger Meter ORION Classic (CE) User Manual

Page 10

Advertising
background image

ORION® Water Endpoints

ORION FIXED NETWORK AND MIGRATABLE ENDPOINTS

This section contains information regarding identification and encoder compatibility for field wiring and activation of ORION

Fixed Network and Migratable endpoints . ORION Fixed Network and Migratable endpoints have a serial number range of

30000000 to 599999999 .

Field Wiring, Encoder Connectivity and Read Resolution

ORION Fixed Network and Migratable endpoints with flying leads are available for connectivity to Badger Meter encoders and

E-Series Ultrasonic meters as well as a number of competitive encoders as shown in chart below .
Endpoints are shipped from the factory pre-programmed and are available in an indoor/outdoor, three-wire configuration for

connection to the encoders listed .

See also

"Endpoint Installation Kits" on page 16

.

All three wires must be connected to complete an installation . The ORION endpoint connection can be made to either existing

wires from the encoder or directly to the terminal screws of the encoder, depending on the application and manufacturer .

Follow the manufacturer’s installation kit instructions provided with the gel splice or field splice kit you are using .

NOTE:

N

For instructions on using gel connectors for field wiring, see

"Using Gel Caps to Connect an Encoder" on page 14

.

ORION endpoint wires:

Red

= Power/Clock; Black = Ground;

Green

= Data

Endpoint

Label

Encoder Connectivity

Endpoint Wire Colors

Red

Black

Green

Reading Resolution

ELCD or ENC

Badger Meter HR-E LCD or HR-E encoders, or
E-Series Ultrasonic Meter with High Res output

Enc

oder W

ir

e/T

ermina

tion

Colors

Red

Black

Green

Up to eight (8) most

significant digits

ADE or ENC

Badger Meter ADE or E-Series Ultrasonic Meter with
ADE output

Red

Black

Green

Up to six (6) most

significant digits

RTR

Badger Meter RTR or E-Series Ultrasonic Meter with
RTR output

Red

Black

Green

Up to seven (7) most

significant digits

ADE or ENC

Elster/AMCo ScanCoder or Invision*

Green

Black

Red

Up to eight (8) most

significant digits

C700D

Elster/AMCo C700 Digital*

Red

Black

Not used –

cut green wire

flush with outer

sheath

Up to seven (7) most

significant digits

ADE or ENC

Master Meter Octave Ultrasonic meter
encoder output

Red

Black

Green

Up to eight (8) most

significant digits

ADE or ENC

Metron Hawkeye*

Red

Black

Green

Up to eight (8) most

significant digits

ADE or ENC

Neptune ProRead, E-coder or ARB-V*

Black

Green

Red

Up to eight (8) most

significant digits

ADE or ENC

Sensus ECR II or ICE*

Red

Black

Green

Up to eight (8) most

significant digits

ADE or ENC

Hersey Translator

Due to the customized, factory wire configurations of the Hersey Translator,
the terminal posts may not match the ORION endpoint wire colors . Please
contact Hersey for the terminal post wiring schematic of your encoders to
determine how the posts correspond to ORION endpoint wires .

NOTE:

N

Competitive encoder output is determined by the encoder configuration .

*ORION Fixed Network and Migratable ADE or ENC endpoints are compatible with the encoders noted above with a manufacture date of 2000 or newer as
long as the encoder is programmed into the three-wire output mode for AMR/AMI and has three wires connected to it . Encoder registers that are currently
in two-wire mode of operation require programming by the Utility, including registers that support auto two- or three-wire detection systems that do not
automatically switch to three-wire mode of operation once a compatible endpoint is connected for ORION connectivity .