INTEGRAL ENDPOINT INSTALLATION

ORION Fixed Network, Migratable and Classic endpoints

are available in an integral configuration, in which the

endpoint and encoder are connected in one assembly .

Mounting an Integral Endpoint on the Meter

An integral endpoint can be installed on any Badger Meter

disc, turbo or compound meter by mounting the assembly

onto the bayonet of the meter and rotating it into its

locking position . See

Figure 26: Integral assembly on meter

.

1 . Loosen the security screw on the endpoint

encoder assembly prior to mounting the assembly

on the meter .

2 . Mount the assembly housing on the

meter bayonet .

3 . Turn the assembly clockwise 1/4 turn to lock the

assembly into place on the meter .

4 . After the assembly is mounted on the meter,

tighten the security screw to secure the assembly

to the register .

Figure 26: Integral assembly on meter

Integral Endpoint with Three Feet of Wire

An integral endpoint can be ordered with three feet of wire

inside the assembly housing . Units with additional wire are

marked “3 Ft Wire” on the side of the integral bracket on

a serial number label . With this option, the endpoint can

be removed from the housing and mounted remote from

the encoder . See

"Removing an Integral Endpoint from the

Assembly Housing" on page 29

.

Figure 27: Additional wire noted on label

Security Screw

Meter Bayonet

3 Ft Wire
noted on
label