Endpoint installation guidelines, Endpoint/encoder connections – Badger Meter ORION Classic (CE) User Manual

Page 7

Advertising
background image

Installation Manual

ENDPOINT INSTALLATION GUIDELINES

ORION endpoints can be installed indoors or outdoors, observing these guidelines:

When

a meter is being installed indoors, the wired radio endpoint should be mounted outside the building or in the

floor joist near an outside wall and away from large metal objects for maximum propagation of the radio signal .

Cellular and Fixed Network endpoints: For pit installations,

m

ounting through a non-metal pit lid is required for

maximum propagation of the radio signal .

Migratable and Classic endpoints: For pit installations,

m

ounting through a non-metal pit lid is recommended for

maximum propagation of the radio signal .

Endpoint/Encoder Connections

ORION endpoints are three-wire metering endpoint devices that require connection to an encoder to complete the assembly .

Available configurations and the encoder connection methods are listed here, based on the endpoint type .

ORION Cellular Endpoint Configurations

ORION Cellular endpoints are available in the following configurations that can be deployed in indoor, outdoor and

pit applications .

Endpoint Configurations

Encoder Connection

Prewired endpoint/encoder assembly with or

without connector

Factory prewired ORION endpoints are shipped connected to a

Badger Meter encoder, ready for installation and require no splicing .

See

"Endpoint Installation Kits" on page 16

.

Endpoint only with Badger Meter in-line

connector (308 or Nicor®)

Connect the endpoint to an encoder using the 308 or Nicor

connectors . See

"308/Nicor In-line Connectors" on page 8

and

"Endpoint Installation Kits" on page 16

.

Endpoint only with flying lead for field splice

See

"ORION Cellular Endpoints" on page 9

for field wiring

information .

ORION Fixed Network, Migratable and Classic Endpoint Configurations

ORION Fixed Network, Migratable and Classic endpoints are available in the following configurations that can be deployed in

indoor, outdoor and pit applications .

Endpoint Configurations

Encoder Connection

Prewired endpoint/encoder assembly with or

without connector

Factory prewired ORION endpoints are shipped connected to a

Badger Meter encoder, ready for installation and require no splicing .

See

"Endpoint Installation Kits" on page 16

.

Prewired integral endpoint/encoder assembly

Mount the assembly on the bayonet of the meter . See

"Integral

Endpoint Installation" on page 28

for details .

Endpoint only with Badger Meter in-line

connector (308 or Nicor®)

Connect the endpoint to an encoder using the 308 or Nicor

connectors . See

"308/Nicor In-line Connectors" on page 8

and

"Endpoint Installation Kits" on page 16

.

Endpoint only with flying lead for field splice

See

"ORION Fixed Network and Migratable Endpoints" on page 10

and

"ORION Classic Endpoints" on page 12

for field wiring information .