ORION® Water Endpoints

ORION CLASSIC ENDPOINTS

This section contains information regarding identification and encoder compatibility for field wiring and activation of ORION

Classic endpoints . ORION Classic endpoints have a serial number range of 70000000 to

199999999 .

Field Wiring, Encoder Connectivity and Read Resolution

ORION Classic endpoints with flying leads are available for connectivity to Badger Meter encoders and E-Series Ultrasonic

meters as well as a number of competitive encoders as shown in chart below .
Endpoints are shipped from the factory pre-programmed and are available in an indoor/outdoor, three-wire configuration for

connection to the encoders listed .

See also

"Endpoint Installation Kits" on page 16

.

All three wires must be connected to complete an installation . The ORION endpoint connection can be made to either existing

wires from the encoder or directly to the terminal screws of the encoder, depending on the application and manufacturer .

Follow the manufacturer’s installation kit instructions provided with the gel splice or field splice kit you are using .

NOTE:

N

For instructions on using gel connectors for field wiring, see

"Using Gel Caps to Connect an Encoder" on page 14

.

ORION endpoint wires:

Red

= Power/Clock; Black = Ground;

Green

= Data

Endpoint

Label

Encoder Connectivity

Endpoint Wire Colors

Red

Black

Green

Reading Resolution

ADE

Badger Meter ADE, HR-E LCD or HR-E encoders,
or E-Series Ultrasonic Meter with High Res or
ADE output

Enc

oder W

ir

e/T

ermina

tion

Colors

Red

Black

Green

Up to seven (7) most significant digits

RTR

Badger Meter RTR or E-Series Ultrasonic Meter
with RTR output

Red

Black

Green

Up to seven (7) most significant digits

UNIV*

Elster/AMCo ScanCoder or Invision

Green

Black

Red

Up to seven (7) most significant digits

UNIV*

Master Meter Octave Ultrasonic meter
encoder output

Red

Black

Green

Up to seven (7) most significant digits

UNIV*

Metron Hawkeye

Red

Black

Green

Up to seven (7) most significant digits

ARB-V*/**

Neptune ARB-V for connectivity to
ORION endpoint > serial number 80000000

Black

Green

Red

Up to seven (7) most significant digits

ARB-V*/**

Neptune ARB-V for connectivity to
ORION endpoint < serial number 79999999

Red

Black

Green

Up to seven (7) most significant digits

UNIV*

Neptune ProRead or E-coder

Black

Green

Red

Up to seven (7) most significant digits

UNIV*

Sensus ECR II or ICE

Red

Black

Green

Up to seven (7) most significant digits

UNIV*

Hersey Translator

Due to the customized, factory wire configurations of the Hersey Translator,
the terminal posts may not match the ORION endpoint wire colors . Please
contact Hersey for the terminal post wiring schematic of your encoders to
determine how the posts correspond to ORION endpoint wires .

NOTE:

N

Competitive encoder output is determined by the encoder configuration .

*ORION Classic UNIV and ARB-V endpoints are compatible with the encoders noted above with a manufacture date of 2000 or newer as long as the encoder
is programmed into the three-wire output mode for AMR/AMI and has three wires connected to it . Encoder registers that are currently in two-wire mode of
operation require programming by the Utility, including registers that support auto two- or three-wire detection systems that do not automatically switch to
three-wire mode of operation once a compatible endpoint is connected for ORION connectivity .

**A separate ORION CE Universal endpoint is available for connectivity to the Neptune ARB-V encoder . Make sure the ORION Classic endpoint has “ARB-V” on
the harness label when wiring to an ARB-V encoder . Wiring differs depending on the serial number of the ORION endpoint you are connecting to the ARB-V
encoder, so make sure to verify wiring is correct per the above chart .

Page 12

June 2014