5-2-5 BUSY Output Terminal Wiring

The “BUSY” output is sent while a message is in playback. Any external devices, such as a signal tower or rotating light,

can be connected and operate during a message playback.

(An external power source is necessary for devices which have no internal power source for operation.)

The maximum voltage for connecting to the BUSY output is DC 40V.

The maximum current for connecting to the BUSY output is DC 500mA.

Connection Examples:

When connecting our rotating lamps, signal towers, etc., please use the following examples.

External Device Connection

with Voltage Source

External Device Connection

with Signal Control

Incorrect Connection Examples:

The following illustrations show examples of how not to connect the BUSY output terminals:

Power inputs outside DC40V or AC supplies connected will cause damage to internal circuitry.

Currents above 500mA will cause damage to internal circuitry.

Incorrect connections like the two examples above will cause damage to internal circuitry.

If inrush current exceeds 5A, damage to internal circuitry will occur.

Incorrect Power

Connection 1

Incorrect Connection 2

(Direct Power Connection)

Incorrect Connection 3

(No Power Connection)

L

L

BUSY- BUSY+

BUSY- BUSY+

+ -

BUSY- BUSY+

+ -

BUSY

BUSY

FV-127JP

Circuit Diagram

L

L

BUSY- BUSY+

BUSY- BUSY+

- +

%CWVKQP

Negative Power

Source

Positive Power

Source

Negative Power Source

Positive Power Source

External Power

Max. DC 40V

External Power with

Internal Power Source

Max. DC 40V

Signal Wire Side

Common Side

Max. 500mA

Max. 500mA