Wiring, Cwvkqp, 1. terminal wiring and names – PATLITE FV-127JP User Manual

Page 8

Advertising
background image

- 8 -

*

Ensure the insulation space is suffi cient with a maximum length of 3mm for the lead wires coming

from the PCB. If an insuffi cient space allows the lead wires to touch a conductive surface, a possibility
of short-circuiting may occur.

Use an 8mm diameter washer. If a washer with a diameter over 8mm is used, contact with the PCB
pattern may cause short-circuiting.

Use all 4 mounting holes when installing and use the recommended torque to prevent the screws from
loosening and the product from unattaching.

%CWVKQP

5. Wiring

5-1. Terminal Wiring and Names

Name

Function

COM

Common connection for input terminals

CH1-7

Channel selection terminal for audio messages. Short to COM for the selected channel to playback message.

Two input modes "binary" and "bit" can be selected. ( ☞ Refer to pg. 23 [7-1. Channel (CH) Terminal Input])

STB

When in the Binary Mode, STB is used during playback. (Not applicable for the “Hold Playback” mode)

( ☞ Refer to pg. 30 [(E) Hold Playback])

STOP

Stops the message during playback.

CLR

When used during the "memory playback" mode, the audio playback message is erased. For other modes,

the function is the same as the "STOP" mode.

DEC1/VOL,

DEC2

Depending on the input status, the speaker volume or AUX volume decreases.

( ☞ Refer to pg. 21 [6-2. Reduction Function])

SP-,

SP+

Speaker Terminal Connection (Note Polarity).

( ☞ Refer to pg. 14 [ ③ Speaker Output Terminal Wiring])

AUX-,

AUX+

Amplifi er Terminal Connection (Note Polarity).

( ☞ Refer to pg. 15 [ ④ AUX Output Terminal Wiring])

BUSY-,

BUSY+

Output is produced during message playback (Note Polarity).

( ☞ Refer to pg. 17 [ ⑤ BUSY Output Terminal Wiring])

24V,0V

Power Input Terminal. Connect DC24V only. (Note Polarity)

( ☞ Refer to pg. 12 [ ① Power Input Terminal Wiring])

FG

When connecting to earth ground (FG), under certain environments can reduce the effect of noise. The FG is

connected internally.

SP-

SP+

AUX- AUX+ BUSY- BUSY+

24V

0V

FG

DEC2

DEC1
/VOL

COM

CH1

CH2

CH3

CH4

CH5

CH6

CH7

STB

CLR

STOP

Input

Terminal

COM

Power Terminals

Output Terminals

CH Input Terminals

M3 Screw

Washer (φ8mm or less)

Spacer

Advertising