- 15 -

5-2-6 Input Terminal Wiring

Connect each terminal through the COM terminal when wiring.

Use relays, switches or other non-voltage contacts or NPN open collector circuitry for operation.

Contact Capacity

Use the following table below to determine the capacity for external connections.

Voltage Capacity

15mA or more

Withstanding Voltage

DC35V or less

Leakage Current

0.1mA or less

"ON" Voltage (V

sat

)

1V or less

Do not connect any inputs to the power or output connections. Possible product failure may occur.

Contact capacity should always be fuse protected. Possible damage to contacts may occur.

10mA

Power Supply

FV-127JP

FV-127JP

External
Device

External
Device

COM

COM

Power Supply

Input

Input

Max. 29V

Max. 29V

10mA

SP-

SP+

AUX- AUX+ BUSY- BUSY+

24V

0V

FG

DEC2

DEC1
/VOL

COM

CH1

CH2

CH3

CH4

CH5

CH6

CH7

STB

CLR

STOP

%CWVKQP