Special command – PATLITE WDR-LE User Manual

Page 47

Advertising
background image

45

Wireless Data Aquisition System Comprehensive User's Manual

Special Command

Command to exchange data between Transmitter and Receiver.

< Special Command List >

Special Command

Command Value

Command Direction

Response

(1) Signal Tower Information

0x00

Transmitter → Receiver (Host)

×

(2) Change Transmitter Mode Setting

0x40

Receiver (Host)→ Transmitter

(3) Change Transmitter Wireless Setting

0x50

Receiver (Host)→ Transmitter

(4) Obtain Transmitter Wireless Setting

0x70

Receiver (Host)→ Transmitter

(5) Receiver Contact Controller

0x30

Host → Receiver

(1) 0x00 :Signal Tower Information

P_Cmd

Special Data

Fixed

Signal Tower Condition Data

Error Code

0x00

0x00

0x00

1 byte

2 bytes

2 bytes

1 byte

① Signal Tower

Condition Data

: Every 3 bits indicates information for Red, Yellow, Green, Blue and White.

bit 15

:Open(0 Fixed)

bit 14-12 :Red Information

bit 11-9

:Yellow Information

bit 8-6

:Green Information

bit 5-3

:Blue Information

bit 2-0

:White Information

(Binary 3 bit Condition)

bit Condition

Signal Tower Condition

000

Unimplemented

001

Off

010

On

100

Flashing

② Error Code

: 0x00 :No Error

0x22 :If information for "Flashing Status" was not previously

carried out, anything outside the indication above is a "Fail" status.