PATLITE WDR-LE User Manual

Page 48

Advertising
background image

46

Wireless Data Aquisition System Comprehensive User's Manual

(2) 0x40 : Change Transmitter Mode Setting

P_Cmd

Special Data

Mode

Mode Data

0x40

1 byte

1 byte

Undetermined

< Mode List >

Mode

Mode Value

Response

a.

Flashing Status

0x02

Pass/Fail

b.

Specifi ed Power Source Line

0x03

Pass/Fail

c.

Mode Readout

0xF0

Mode Data

① Detailed Mode Data for each Mode

a. Flashing Status【Mode Data:1 byte】

0x00:Flashing On

0x05:Flashing Off

b. Specifi ed Power Source Line 【Mode Data:1 byte】

0x01:Red

0x02:Yellow

0x03:Green

0x04:Blue

0x05:White

c. Mode Readout 【Mode Data:0 byte】

No Mode Data

② 【Response】

a. Pass/Fail

P_Cmd

Special Data

Status

0x40

1 byte

1 byte

Status

0x01 :Pass
0xFF :Fail

b. Mode Data

P_Cmd

Special Data

Unimplemented

Flashing Status

Specifi ed Power

Source Line

Unimplemented

0x40

1 byte

2 bytes

1 byte

1 byte

1 byte

The setting value for the "Flashing Status" and "Specifi ed Power Source Line" is returned in the

format indicated above.

Advertising