Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 100

Advertising
background image

BLN1-600A

Chapter 7: Appendix

100 of 116

Programmable Settings
The Batch blender software program has been designed to allow some customizing to achieve
certain desired operating parameters. The following is a listing of the selections that are
“field” programmable, followed by the procedure for doing so.

This menu is accessed by pressing the manufacturer’s icon when in the “Setup” Directory
Screen menu.

Enter the long password “3145348” and press “Enter”.

Advanced Setup Menu
Metering Test Screen

This screen is useful when testing the metering performance of each feeder. The user can
perform test to evaluate the mechanical standard deviation of the gate or auger. This test
meters for the calculated time based off the target weight entered on this screen. The blender
does not retry or adjust the time of the meter to reach the target. This allows you to open the
gate for several feeds using the same time. You can then record the Dispensed Grams and
plot the standard deviation of the gate. The other purpose of this screen is to verify that the
dispensed weight displayed is correct. You can perform a meter and then pull the weigh
hopper to weigh the material on a gram scale. Refer to the Troubleshooting Section of this
manual for additional details.

Touch here and enter
in the Supervisor or
Maintenance
Password to access
the Advanced Setup
Menu

Enable/Disable
Security

Advertising