Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 43

Advertising
background image

BLN1-600A

Chapter 3: Installation

43 of 116

Weigh Hopper Installation

Remove the weigh hopper from the shipping box and install it in the blender on the load cell
brackets. Connect the airline and close the mixer door, securing the latch.

Figure 25: Weigh Hopper

Final Connections

Connect the blender to the appropriate power source.

Connect the compressed air piping, ensuring that a 5-micron air filter is installed, along with
the proper water trap, and lubrication unit, if required. Verify that 60 psi (4.14 bar) of clean,
dry compressed air is supplied to the blender.

THE WEIGH HOPPER ASSEMBLY MUST HANG FREELY AND BE

FREE FROM FRICTION, WITH NO MECHANICAL OBSTRUCTIONS
OTHER THAN THE LOAD CELL ITSELF.

Again, make sure that proper air supply connections are made to the

blender, as dirty, contaminated, wet air can damage blender components
and can quickly cause poor performance and accuracy!

Make sure that the blender is supplied with clean, dry,

60 psi (4.14 bar) compressed air.