Weigh Hopper (Load Cell) Calibration

(Recommended only if the calibration is out of spec)













1. The blender must be stopped before this can be done.

2. From the Setup Menu touch “Calibration” and then “Scale Calibration”.

3. Enter in the scale calibration weight value stamped on the side of the weight.

4. The controller will prompt you to remove the weight hopper and press OK.

5. After touching OK, the controller will display “PLEASE WAIT...”

6. Next, the controller will ask you to hang the calibration weight on the right loadcell

bracket (loadcell A) and press OK.

7. The controller will ask you to hang the calibration weight on the left loadcell bracket

(loadcell B) and press OK. (Does not apply to the BD-150)

8. Finally, the controller will ask you to replace the weigh hopper in the blender and

press OK to complete the calibration.

9. The controller will verify that the calibration was done correctly by showing

“Calibration Successful.”

10. Press “X” until you have reached the Recipe screen.

Follow Instructions

Enter in the
Calibration Weight

Current Loadcell Bits