Chapter 4: Operation

68 of 116

Mixer and Dump Setup

Mixer Options

Press the “Timed/Continuous Mixing” key (In the top right hand corner) when in “Mixer and
Dump Setup” screen to set the following options:

Timed Mixing Option

This mode of operation turns the mixer on only during dumping and during the re-mix
time set into the control to jog the mixer during high level mixer operation.

Continuous Mixing Option

This mode of operation turns the mixer on after initial startup and will continue to run
continuously, unless the remix time is set to jog the mixer during high level mixer
operation. This option is used for sticky materials that tend to bridge and block off the
mixer discharge to the processing machine.

Mix Timer

The mix timer is the amount of time that the mix motor will mix the material after it has
entered the mixing section of the Batch blender. The timer has a range of 1 to 999 seconds.

To set the value of the mix timer, the user must gain access to the Setup Menu. After entering
the Setup menu, the user must select “Mixer and Dump Setup.”

Figure 40: Typical Mixer and Dump Setup Operator Screen

Selecting “Mixing Time” from the “Mixer and Dump Setup” menu will allow the operator to
view the current time setting for the mix timer and to adjust it as needed.

Re-Mix Timer

In some applications, the Batch blender will require the use of the re-mix timer. Some
materials tend to separate if they are mixed too long. This is possible when a processing
machine is running at a rate significantly below the capacity of the blender.

With external vibration, the heavier pellets will tend to flow to the bottom of the mix chamber
before the lighter material. This will occur even though the mixer is in a static mode. By re-
mixing occasionally, this situation will be prevented.

The re-mix timer will start another mixing cycle if the blender has been idling long enough
for the re-mix timer to time out. The re-mix timer may be set on the “Mixer and Dump Setup”
screen from 1 to 999 seconds. Setting the re-mix timer to zero will disable this function.

If the re-mix timer is disabled, the controller will run only a single, timed mix cycle after each
dump of the weigh hopper.