Sterlco SGBD Series Batch Gravimetric Blenders User Manual

Page 47

Advertising
background image

BLN1-600A

Chapter 3: Installation

47 of 116

Verify Weigh Hopper (Load Cell) Calibration











Verifying Calibration (Recommended on a periodic basis to ensure accuracy)

1. The blender must be stopped before this can be done.

2. From the Setup Menu touch “Calibration” and then “Direct Scale Readout”.

3. Remove the weigh hopper.

4. Locate the weight display for each of the two load cells. Write down the displayed

value.

5. Add the calibration weight to each load cell mounting bracket and write down the

value displayed in “weight”, as in step 4.

6. Subtract the values recorded in step 4 from step 5. This is the measured weight. If

the measured weight is within a 0.003 pounds of the weight stamped on the
calibration weight, then you are within spec. If not, follow the steps above to
calibrate the blender. (If your blender is frequently out of calibration, verify the
operator is being cautious removing the weigh hopper during clean out.)

7. Press “X” until you have reached the Recipe screen.

Weight for each loadcell

Advertising