Ccm appliance commands, Connect command, Disconnect command – Avocent CCM4850 User Manual

Page 53: Chapter 5: ccm appliance commands, Connect command disconnect command, Table 5.1: connect command parameter

Advertising
background image

41

CHAPTER

5

CCM Appliance Commands

Connect Command

The Connect command establishes a connection from the CCM console management appliance
console port to a device attached to another port on that CCM appliance. To use this command, you
must have previously issued a Server CLI command with the Connect=On parameter. For more
information, see Connecting to Serial Devices on page 12.
Access right: port-specific
Access level: ADMIN, APPLIANCEADMIN or others with access to port

Syntax

CONNECT <port>

Example

The following command establishes a connection from the serial console port to port 6.

> connect 6

Disconnect Command

The Disconnect command terminates a session with a serial device that was previously initiated
with a Connect command. This command frees the serial port and allows other users to access it.
Access right: port-specific
Access level: ADMIN, APPLIANCEADMIN or others with access to port

Syntax

DISCONNECT

Table 5.1: Connect Command Parameter

Parameter

Description

<port>

Port number in the range 1-48.