Allied Air Enterprises 80G1UH User Manual

Page 21

Advertising
background image

506526-01

Page 21 of 39

Issue 1031

Vent Connector Capacity

Type B Double Wall Vents with Single Wall Metal Connectors

Serving Two or More Category I Appliances

Table 7

Common Vent Capacity

Type B Double Wall Vents with Single Wall Metal Connectors

Serving Two or more Category I Appliances

Table 8

NOTE: Single appliance venting configureations with zero lateral lengths are assumed to have no elbows in the vent system. For all other vent

configurations, the vent system is assumed to have two 90 ° elbows. For each additional 90° elbow or equivalent (for example two 45° elbows equal

one 90° elbow) beyond two, the maximum capacity listed in the venting table should be reduced by 10 percent (0.90 x maximum listed capacity).