Thermostat Heat Anticipation

Set the heat anticipator setting (if adjustable) according to

the amp draw listed on the wiring diagram that is attached

to the unit.

NOTE: Do not secure the electrical conduit directly to the

air ducts or structure.

Electrical

1. Check all wiring for loose connections.

2. Check for the correct voltage at the furnace (furnace

operating). Correct voltage is 120VAC ± 10%.

3.Check amp-draw on the blower motor with inner blower

panel in place.

Unit Nameplate__________ Actual _______________

Blower Speeds

Follow the steps below to change the blower speeds.

1. Turn off electrical power to furnace.

2. Remove blower access panel.

3. Disconnect existing speed tap at integrated control

speed terminal.

NOTE: Termination of any unused motor leads must be

insulated.

4. Place unused blower speed tap on integrated control

“PARK” terminal or insulate.

5. Refer to blower speed selection chart on unit wiring

diagram for desired heating or cooling speed. See

Blower performance data beginning on the next page.

6. Connect selected speed tap at integrated control speed

terminal.

7. Resecure blower access panel.

8. Turn on electrical power to furnace.

9. Recheck temperature rise.

Electronic Ignition

The integrated control has an added feature of an internal

control. The feature serves as an automatic reset device

for integrated control lockout caused by ignition failure. This

type of lockout is usually due to low gas line pressure. After

one hour of continuous thermostat demand for heat, the

control will break and remake thermostat demand to the

furnace and automatically reset the integrated control to
begin the ignition sequence.