8 troubleshooting external storage xp, 12 general external storage xp troubleshooting, Troubleshooting external storage xp – HP StorageWorks XP Remote Web Console Software User Manual

Page 121: Troubleshooting external, Storage xp, 8troubleshooting external storage xp

Advertising
background image

External Storage XP user guide 121

8

Troubleshooting External Storage XP

If you have a problem with the Command View XP computer or Command View XP or XP Remote Web

Console software, see the HP StorageWorks Command View XP user guide for XP Disk Arrays or the

HP StorageWorks XP Remote Web Console for XP12000/XP10000/SVS200 for troubleshooting

information.
For additional assistance, contact your HP account support representative.

Table 12

provides general troubleshooting instructions for External Storage XP operations.

Table 12

General External Storage XP troubleshooting

Error

Corrective action

The Command View XP

management station or XP

Remote Web Console cannot

access the external LU.

Correct the error and retry the operation.
The reason for the error could be one of the following:

The Fibre Channel (FC) switch is off or an error occurred in the switch.

The FC cables are not properly connected.

The configuration of the external array changed, and the external LU was

deleted.

An error occurred with the external LU in the external array.

The path in the external array changed.

The port attribute of the local array is no longer external.

The topology information is not set correctly.

The external LU cannot be

mapped as an internal LDEV

of the local array.

Correct the error and retry the operation.
The source of the error could be any of the following:

The number of mapped external LUs exceeds the maximum number (15,360

LUs for XP12000 or 8,192 LUs for XP10000/SVS200) available for the local

array.

There are not enough CU:LDEV numbers available for external LU mapping.

The path to the external LU is

blocked.

1.

The errors listed in the first row of this table (Error: The Command View XP

management station or XP Remote Web Console cannot access the external

LU) could be the reason for this error. Check the reasons in the first row,

correct the error, and retry the operation. If the error persists, try step 2b.

2.

Try the following procedures. If they do not work and the path is not restored,

contact your HP account support representative.
a. Verify that the cable between the local array and external array is

connected properly.

b. If the cable between the local array and external array is connected

properly, disconnect and reconnect it. After 30 seconds, check the path

status from Command View XP or XP Remote Web Console.

The status appearing in the

Ex-Dev. Status column is

Normal, but the status

appearing in the LDEV Status

is Unknown.

The LDEV’s status cannot be determined. This occurs when the LDEV does not

exist. The reason for the error could be:

The LDEV was been created when the volume was mapped.

The LDEV in the external LU was deleted by the Volume Manager function.

If

LDEV Status

becomes

Unknown

by any reason other than above, contact you

HP account support representative.

The path status that requires

the action appears in the

Alternate Path list on the Path

Setting window (see

Setting

alternate paths for external

LUs

” on page 86).

The following rows describe path status values displayed in the Alternate Path list

and corrective actions for each status value. See ”

Notes on connecting external

arrays

” on page 127 for notes on connection settings and examples of recovery

procedures, and then take the corrective action.