142 Required volume capacity for emulation types

Figure 69

shows the relationship of the minimum LDEV capacity, base LDEV capacity, minimum data area

capacity, base data area capacity, and control information area capacity.

Figure 69

LDEV capacity

Figure 70

shows how to determine the volume capacity using the example of the OPEN-3 case.

Figure 70

Calculating LU capacity (OPEN-3 example)

Table 26

lists the minimum data area capacity, base data area capacity, and control information area

capacity for each emulation type. For the OPEN-L emulation type, CVs cannot be created. Therefore, the

base data area capacity and minimum data area capacity for OPEN-L emulation type are the same. For

the OPEN-V emulation type, the base data area capacity is not listed because there is no concept of the

base data area capacity.

Table 26

LDEV capacity information for each emulation type

Emulation type

Minimum data area

capacity (blocks)

Base data area

capacity (blocks)

Control information

area capacity (blocks)

3380-3

72,000 4,808,160

10,080

3380-3A

72,000 4,808,160

10,080

3380-3B

72,000 4,808,160

10,080

3380-3C

72,000 4,808,160

10,080

3380-K

72,000 3,823,200

10,080