Selecting the location, Figure 9, Recommended mast location in an open area – Vaisala WMT52 User Manual

Page 30

Advertising
background image

User’s Guide ______________________________________________________________________

28 ___________________________________________________________________M210925EN-B

Selecting the Location

Finding a suitable site for WMT52 is important for getting
representative ambient measurements. The site should represent the
general area of interest.

The WMT52 should be installed in a location that is free from
turbulence caused by nearby objects, such as trees and buildings. In
general, any object of height (h) will not remarkably disturb wind
measurement at a minimum distance of 10 h. There should be at least
150 m open area in all directions from the mast. Refer to

Figure 9 on

page 28

.

0806-004

Figure 9

Recommended Mast Location in an Open Area