26

Installation and Programming Manual

Chapter 4: Programming

Program Position Offset (302)

13. Select the function key.

The monitor displays “F----”.

14. Select function number 302 (Position Offset Function). Select the enter key.

The monitor displays the current position.

15. Enter the actual or desired machine position reading. Select the enter key.

After confi guring the encoder module for use with a resolver, you can proceed

to Section 4.3: Monitor Setup functions.

302

Enter desired
reading

Display Power Up (305)

16. Select the function key.

The monitor displays “F----”.

17. Select function number 305 (Power Up Function). Select the enter key.

The monitor displays 0 or 1.
0 = Power Up Displaying Position
1 = Power Up Displaying RPM

305

18. Enter 0 or 1. Select enter key.

Enter 0 or 1

Resolver Reset-to-Preset (307)

19. Select the function key.

The monitor displays “F----”.

20. Select function number 307 (Resolver Reset-to-Preset). Select the enter key.

The monitor displays current value.

The reset-to-preset input is an edge sensitive input that resets position data to a preprogrammed
value. An open collector sinking device or dry contact applied to these terminals activates
the input.

307

This function is used to set what will be displayed on Power Up.

(F)

(F)