AMETEK 2120 PLC Interface Module User Manual

Page 53

Advertising
background image

Installation and Programming Manual

Appendix A: Error Messages

49

The following errors will cause the upper and lower limit relays to de-energize:

Chart A-5 Upper and Lower Limit Relay Errors

The following chart contains a resolver-specifi c error:

Chart A-6 Resolver-Specifi c Error

Error Displayed

Error Description

SEr320

SEr330

This is a resolver-specifi c error See Chart A-6

The input device is not connected to the monitor’s input module

SEr331

This is a LDT-specifi c error See Chart A-7

OEr101

The machine did not move within the time programmed in the Move Detection
Time-out function

OEr330 or
OEr320

The Interface Module moved beyond the value programmed in the Negative
Over Travel Limit function

Error Displayed

Error Description

Solution

SEr320

The cable may not be connected, an open or short
may exist in the cable, or the resolver’s primary may
be open or shorted

To determine the exact condition,
enter the Error Conditions func-
tion (306). For instructions, see
Error Conditions (306) following
this chart