Status leds defi ned, Relay output (fmor01) – AMETEK 2120 PLC Interface Module User Manual

Page 9

Advertising
background image

Installation and Programming Manual

Chapter 2: Hardware Overview

5

2.3: Status LEDs Defi ned

The Interface Module has 10 status LEDs and four programming keys. The LEDs provide information on
the monitor’s state during machine operation, and the programming keys are used to program functions

and perform basic operations.

Figure 2-2 Status LEDs and Programming Keys

PROGRAM

The program LED turns on when the Interface Module is in program mode and

turns off when it is not. Functions cannot be programmed when this LED is off.

FAULT

OK

The fault check OK LED turns on when the power supply’s fault check relay is

energized, indicating the system is OK. This LED will turn off when a fault is

detected, indicating that the fault check relay is deenergized.

MVT FLT

The movement fault LED turns on when a movement fault is detected. (For more

information, see Move Detection Time-out in Section 4.3: Setup Functions.)

Relay Output (FMOR01)

This optional module contains two overtravel limit relays. These relays can be programmed to either
energize or deenergize upon reaching the programmed overtravel position. These relays will also actuate
upon detection of the system and operating errors listed in chart A-5 in Appendix A.

Status LEDs

Shift Key

Scroll Key

Function Key

Enter Key

AUX 3

AUX 2

AUX 1

PROGRAM

FLT OK

MVT FLT

POSITION

UPR LIM
LWR LIM

RPM

2120

SERIES

F

( )

Advertising