366 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server

Local and Phantom Power

An attendant console’s maximum distance from the system is limited.
See

Table 21: Attendant Console Cabling Distances

on page 366.

1152A1 mid-span power distribution unit

The 1152A1 Mid-Span Power Distribution Unit (PDU) is an Ethernet power supply that provides
power to up to 24 46xx-series IP telephones or wireless LAN (WLAN) access points. This unit is
used with a 10/100BaseTx standard Ethernet network over a standard TIA/EIA-568 Category 5,
6 or 6e cabling plant. The 1152A1 meets the current requirements of the IEEE802.3af standard
for resistive detection.

The 1152A1 PDU complies with the Underwriters Laboratories Inc. (UL) standard UL 1950,
second edition.

For safety instructions, see

Important 1152A1 PDU Safety Instructions

on page 367. For

installation instructions, see

Connecting the 1152A1 PDU cables

on page 368.

Table 21: Attendant Console Cabling Distances

Enhanced Attendant
Console (302D)

24 AWG Wire (0.26
mm

2

)

26 AWG Wire (0.14
mm

2

)

Feet Meters

Feet Meters

With Selector Console

Phantom powered

800

244

500

152

Locally powered

5000

1524

3400

1037

Without Selector
Console

Phantom powered

1400

427

900

274

Locally powered

5000

1524

3400

1037

Table 22: 1152A1 PDU UL 1950 Compliance