INSTALLATION

SITE PREPARATION
1. Structure: Your spa should always be installed on a structurally sound,

relatively smooth, and level surface.

2. Electrical: Your spa should be connected to a grounded outlet within

eight feet of the spa. For 120 V units, there should be easy access to the

plug for periodic testing of the cord mounted GFCI.

3. Bonding: A copper wire connector is located inside the spa power pack to

permit connection of a minimum No. 8 A.W.G. (No. 6 for Canada) solid

copper bonding conductor between any metal equipment, water pipe, or

metal enclosures within 5 feet of the spa as required to comply with the

National Electric Code, or local requirements.

INDOOR INSTALLATION
Give special consideration to the following issues when installing your spa

indoors.

1. Make sure the fl oor can support the total spa fi lled weight of 2113 pounds.

2. Install your spa on water resistant, non-slip fl oor. Th e fl oor should have

a drain to remove water splashed from the spa. Do not install the spa on

carpet or other material that will be damaged by moisture.

3. Take into consideration the room humidity which will exist due to

high temperatures. Providing natural or forced ventilation in the room

will help maintain comfort and minimize moisture damage to the

surrounding environment.

4. Avoid installing the spa indoors on a second story above fi nished living

space due to the possibility of water and humidity damage.

5. Allow enough clearance around the spa for full access to the spa

equipment for service.