Before you can upgrade a Campus-RS unit, you must first download the
firmware file(s) to your computer. These files are available on the ADC Web
site, www.adc.com.

1

From the Main Menu, type

then press

. The Diagnostics menu

displays.

2

Type

and press

to select Download Mode.

3

Type

and press

to confirm the selection.

The console freezes and the Test LED on the line unit or desktop unit
front panel illuminates, indicating that the Campus-RS unit is in
Download Mode.

4

Close the terminal emulation program you are using for the ASCII
terminal.

5

Start the Download Utility (DNL32.exe).

4

ENTER

May 3, 1999

ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx

13:29:35

Local Unit ID:

Campus-REX Unit #34

Local I/F:

REX

Remote Unit ID: Campus-REX Unit #12

Remote I/F: REX

Circuit ID:

Network Extension Circuit 5001

DIAGNOSTICS MENU

1)

LOOPBACK SETTINGS MENU

2)

DOWNLOAD MODE

(R)eturn

ENTER CHOICE>

2

ENTER

Y

ENTER