Compatibility with campus-rs products, Compatibility with campus-rs products -4, Rs p – ADC Campus-REX RS Interface Card User Manual

Page 16: Ompatibility, With, Ampus, Roducts

Advertising
background image

About the Product

1-4

Campus-REX RS Interface Card User Manual

C

OMPATIBILITY

WITH

C

AMPUS

-RS P

RODUCTS

The Campus-REX RS Interface Card is also compatible, over the HDSL link,
with another Campus-RS unit, as shown in the following illustration.

When connecting to another Campus-RS Desktop Unit or Line Unit,
Standard Mode is still supported, providing access to HDSL transmission
rates of T1, E1 and 768 kbps. In addition, the Campus-RS system can be
configured to support an extended set of HDSL transmission rates, over either
one or two HDSL loops.

To support these additional transmission rates, set the following options on
the Campus-REX:

Set the HDSL Operating Mode to Extended Mode or AutoSync Mode.

Set the Extended Mode Loop Configuration to 1 Loop or 2 Loops,
depending on the physical layout of your HDSL network.

Set the Extended Mode HDSL Rate to the desired setting.

Campus-RS
Interface card

Campus-RS

Campus-RS

HDSL

Campus-REX RS

Interface card