Autosync alarms, Viewing 24-hour hdsl alarm history -7, Autosync alarms -7 – ADC Campus-REX RS Interface Card User Manual

Page 67

Advertising
background image

Configuring and Monitoring through the LCD

Campus-REX RS Interface Card User Manual

4-7

Viewing 24-Hour HDSL Alarm History

You can view the number of HDSL alarm conditions that have occurred over
the past 24 hours. The LCD displays 24-hour information for the following
alarms:

local errored seconds (

LOCAL ES

)

remote errored seconds (

REMOTE ES

)

local unavailable seconds (

LOCAL UAS

)

remote unavailable seconds (

REMOTE UAS

)

You may also view the time when the counter was last cleared and clear the
counter.

To view the HDSL alarm history:

1

Press Escape until

CAMPUS RS I/F: REX

displays.

2

Press Next.

HDSL LINK CONFIG & STATUS

displays.

3

Press Enter, then press Next until

PERFORMANCE STATUS

displays.

4

Press Enter, then press Next to scroll through the alarm history displays.

5

To reset the counter, press Next until

Press ENTER to clear

error cnts

displays, then press Enter.

AutoSync Alarms

The system generates an AutoSync alarm if the HDSL Operating Mode is set
to AutoSync and an HDSL connection cannot be established in AutoSync
Mode. This alarm is generated even if the HDSL link is eventually established
through Fallback Mode. This section describes how to view and configure
this alarm.