AT-FS970M Switch Command Line User’s Guide

1347

The fields are described in Table 142.

Example

The following example displays the RMON alarms on the switch:

awplus# show rmon alarm

Table 142. SHOW RMON ALARM Command

Parameter

Description

Alarm Index

The ID number of the alarm.

Variable

The MIB object the alarm is monitoring,
and the ID number of the statistics group
used to monitor the port and MIB object.

Interval

The polling interval in seconds.

Alarm Type

The alarm type. This is always “rising and
falling,” meaning the alarm has both a
rising threshold and a falling threshold.

Rising Threshold

The rising threshold.

Event Index

The ID number of the event the alarm
performs if the rising threshold is crossed.

Falling threshold

The falling threshold.

Event index

The ID number of the event the alarm
performs if the falling threshold is crossed.

Owner

The name of the owner of the alarm. The
owner is Agent if no owner was specified
when the alarm was created.