Appendix

149

Restoring Original Factory Default Settings

You can restore the original factory default settings for the KM0832 Matrix
KVM Switch. The original password for the default super administrator
account is restored; all super administrator, administrator, user, and group
accounts are removed from the system. Only the station name, Webpage
Session Timeout setting, network settings, and date and time are retained. This
procedure requires the use of a jumper cap.

1. Turn off the KM0832 and unplug the power cord.

2. Remove the cover of the KM0832.

3. Place a jumper cap over pins 1-2 of the J3 jumper on the mainboard.

4. Plug in the power cord and turn on the KM0832. The following directions

appear on the KVM console screen:

USERNAME AND PASSWORD INFORMATION AND PORT/USER

INFORMATION HAS BEEN CLEARED. PLEASE POWER OFF THE

SWITCH, REMOVE THE JUMPER, CLOSE THE CASE, THEN

RESTART.

(Continues on next page.)

J8

J3